Strona 1 - Owner’s Manual

1833, 1834, 1835, 1837 PC Programmable Telephone Entry and Access Control Systems DoorKing, Inc.120 Glasgow AvenueInglewood, California 90301U.S

Strona 2

1.2 Surface Mount Units Surface mount units can be mounted directly to a wall or pilaster, or can be post mounted using a DoorKing Architectural Style

Strona 3

1.3 Surface Mount Units with Recess Box Surface mount units can be semi-flush mounted into a wall or pilaster by using the optional recess-mounting b

Strona 4 - TABLE OF CONTENTS

1.4 Flush Mount Units Flush mount units are installed into a wall with flush mount kits 1814-065 (stainless) or 1814-066 (gold). Flush mount kits are

Strona 5 - Section 4 – Adjustments

1.5 Flush Mount Rough-in Box The flush mount installation kit has two parts; the rough-in box and the trim ring. The rough-in box is installed first

Strona 6 - IMPORTANT NOTICE

1.6 Flush Mount Trim Ring Flush mount units can be mounted by using the 1814-065 (stainless) or 1814-066 (gold) mounting kit. Flush mounting kits ar

Strona 7 - GENERAL INFORMATION

1.7 Flush Mount Surface Mounting Kit Flush mount units can be surface mounted by using the optional 1814-152 surface mount trim ring. Flush mount un

Strona 8 - FEATURES

1.8 Wall Mount Units Wall mount units are designed to be mounted directly onto a wall without the need of cutting a large hole as is necessary with f

Strona 9 - SECTION 1 - INSTALLATION

1.9 Memory Chip Installation The telephone entry system is shipped with two memory chips packaged in a separate box inside the shipping container. T

Strona 10 - 1.2 Surface Mount Units

1.10 Postal Lock Installation At some locations, such as gated communities, it will be necessary to provide access to the mail carrier so that they c

Strona 11

SECTION 2 – WIRING Prior to installing wiring to the telephone entry system, we suggest that you become familiar with the instructions, illustrations

Strona 13 - Flush Mount Rough-in Box

2.1 Wiring Guidelines Do not run high voltage (115 V) power lines and communication lines in the same conduit. These should be in separate conduits

Strona 14 - 1.6 Flush Mount Trim Ring

2.2 Terminal Descriptions MAIN DESCRIPTION 1 Phone Line Connection – 800 ft. maximum with 24 AWG wire; 1600 ft. maximum with 22 AWG wire. 2 Phone Li

Strona 15

2.3 Wiring Detail 2.3.1 Controller Only C.O.PHNElevatorControlRS 232ConnectionAuxiliary TerminalsMain TerminalRelay 04 51833, 1834, 1835, 1837, 1838 C

Strona 16 - 1.8 Wall Mount Units

2.3.2 Controller & Expansion Boards 1-8 C.O.PHNElevatorControlRS 232ConnectionAuxiliary TerminalsMain TerminalRelay 04 51833, 1835, 1837, 1838

Strona 17

2.3.3 Controller & Expansion Boards 1-16 Main Terminal1833, 1835, 1837, 1838 CONTROLLERNOTES: Controller main terminals 15-16-17 = SYSTEM RELAY 1

Strona 18

2.4 RS-232 Cable Connection P/N 1818-0401569123456REDBLACKWHITEBROWNGREENSHIELDDOORKING, INC., INGLEWOOD, CA 90301Date: Dwg. No.Detail Wiring - 30 S

Strona 20 - 2.1 Wiring Guidelines

SECTION 3 – PROGRAMMING IMPORTANT! Many of the advanced features available with this telephone entry system cannot be programmed from the system key

Strona 21 - 2.2 Terminal Descriptions

3.1.2 Programming from the Keypad Follow the programming instructions as described in each section of this manual. The system will prompt you with s

Strona 22 - 2.3 Wiring Detail

3.2 Programming with a PC Prior to programming the PC Programmable Telephone Entry System with the DoorKing Remote Account Manager for Windows softwa

Strona 23 - Detail Wiring

3Use this manual with the following models only. 1833, 1834, 1835 and 1837 Telephone Entry Systems, REV C or Higher. DoorKing, Inc. reserves the ri

Strona 24

3.2.3 PC Programming Table The information in the chart will be required when you program the PC programmable telephone entry system from your PC. T

Strona 25 - 2.4 RS-232 Cable Connection

3.3 General Programming Proceed with the programming steps on the following pages only if PC programming will not be used. 3.3.1 Relay Strike Time

Strona 26

3.3.3 Tone Open Numbers These steps will program the tone open numbers for relays 0, 1 and 2. You will need to enter a four-digit number (see chart

Strona 27 - SECTION 3 – PROGRAMMING

3.3.5 Touch-tone / Rotary-dial This programming sequence will set the telephone entry system to dial out in either a touch-tone or rotary format. Ge

Strona 28

3.4 Programming Letters, Numbers and Messages These programming steps apply only to the 1834, 1835 and 1837 systems. The keypad on these systems hav

Strona 29 - 3.2 Programming with a PC

3.4.2 Programming the User Message – 1834, 1835 Systems The user message, followed by the instruction message, scrolls across the screen from right t

Strona 30 - (circle one)

3.4.3 Programming the Instruction Message – 1834, 1835 Systems The instruction message scrolls across the screen from right to left when the system i

Strona 31 - 3.3 General Programming

3.4.4 Programming the User Message – 1837 Systems The user message is displayed on the top four lines of the 1837 display. This message can be a max

Strona 32 - DIGIT FUNCTION

3.4.5 Programming the Instruction Message – 1837 Systems The instruction message is displayed on the bottom four lines of the 1837 display. This mes

Strona 33

3.5 Programming Phone Numbers and Names Before beginning manual programming of this telephone entry system from the keypad, it is strongly recommende

Strona 34

TABLE OF CONTENTS Preface Important Notices...

Strona 35

3.5.1 Programming the Directory Code Length This programming sequence sets the directory code length to 1 - 2 - 3 or 4 digits. If 11 or more residen

Strona 36

3.5.3 Programming Area Codes Up to 10 different area codes can be programmed for any 10-digit or long distance calling requirements and will be refere

Strona 37

3.5.5 Programming Names (1834, 1835, 1837 Systems Only) In this section, names will be programmed into the system. Names are referenced to a phone n

Strona 38

3.5.8 Delete Area Codes This program sequence deletes area code numbers that have been programmed into the system. 1. Press *24 and enter the four-d

Strona 39

3.6 Programming Device Codes (1833, 1835, 1837 Only) Device codes must be five (5) digits in length and are typically card and transmitter codes. Ea

Strona 40

3.7 Programming Four Digit Entry Codes Four digit entry codes are entered on the system keypad preceded by # to allow the resident access. Do not co

Strona 41

3.8 Anti-pass Back (1833, 1835, 1837 with APB Chip Set Only) The programming steps below will allow you to set up and program some basic functions fo

Strona 42

SECTION 4 – ADJUSTMENTS DOORKING, INC., INGLEWOOD, CA 90301Date: Dwg. No.1830 Series Board AdjustmentsRev.Title:3/03AM1835-065-61231413121110987654

Strona 43

4.1 Speaker Volume, Microphone and Feedback Speaker volume, microphone volume and feedback all interact with each other to affect the audio performan

Strona 44

4.4 Back-light Cutoff 1. This is a factory set adjustment and should not be adjusted in the field. 4.5 Master Code Switch 1. The master code swi

Strona 45

3.5 Programming Phone Numbers and Names ...39 3.5.1 Progra

Strona 47 - SECTION 4 – ADJUSTMENTS

SECTION 5 – OPERATING INSTRUCTIONS 5.1 Guest Instructions Instructions on the telephone entry systems guide guest on the usage of the system and how

Strona 48

5.2 Resident Instructions Resident control of the door or gate that the telephone entry system controls is limited to opening the door or gate in resp

Strona 49

5.3 System Administrator The administrator can perform the following operations from a remote location using a touch tone telephone. You must know th

Strona 50

5.3.3 Relay Check The telephone entry system can be called and a check can be made to determine if any of the relays in the system are in a "ho

Strona 51 - 5.1 Guest Instructions

5.4 Miscellaneous Operating Instructions 5.4.1 Talk Time The talk time for directory codes 0, 00, 000, 0000 and 1, 01, 001, 0001 is factory set to 4

Strona 53 - 5.3 System Administrator

SECTION 6 – MAINTENANCE The DoorKing telephone entry system is essentially a maintenance free device. When the unit is properly installed, it should

Strona 54

SYMPTON POSSIBLE SOLUTION(S) Cannot get into programming mode. • Wrong master code entered. Start over. • Waiting too long between pushing buttons.

Strona 55

SYMPTON POSSIBLE SOLUTION(S) Four-digit entry codes will not work. • Forgetting to press # first. • Re-program the entry code ranges (3.7.3). Entry

Strona 56

IMPORTANT NOTICE FCC - UNITED STATES This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Par

Strona 57 - SECTION 6 – MAINTENANCE

6.1.2 Weigand Test (1835, 1837 Systems Only) This programming sequence will allow you to view the weigand data on the display as it is received by th

Strona 58 - SYMPTON POSSIBLE SOLUTION(S)

6.1.4 Elevator Board / Floor Hardware Test This testing sequence will allow you to check activation of individual relays on the elevator control boar

Strona 59

6.2 Accessories Surface Trim Ring Use to recess a surface mount unit into a wall or column. P/N 1803-150. Flush Kit Use to install flush style uni

Strona 60

6.3 Log Tables Complete the information in the tables on the following pages to maintain a record of the information that has been programmed into the

Strona 61

NAME AAC PHONE NUMBER DIR CODE ENT CODE DEVICE CODE SEC LEVEL FL ER

Strona 62 - 6.2 Accessories

Resident Instruction Sheet Your building / community has been equipped with a DoorKing Telephone Entry System that will provide communication for y

Strona 63 - 6.3 Log Tables

GENERAL INFORMATION • Prior to beginning the installation of the telephone entry system, we suggest that you become familiar with the instructions,

Strona 64

FEATURES • Can provide service for up to 3000 residents. • Can store up to 8000 card, transmitter or digital PIN codes (not applicable to 1834). •

Strona 65 - Resident Instruction Sheet

SECTION 1 - INSTALLATION Order your telephone line at least two weeks prior to the planned installation date. This will assure that a phone line is